Geobacillus Stearothermophilus 0.4ml Capsule

Geobacillus Stearothermophilus 0.4ml Capsule
Geobacillus Stearothermophilus 0.4ml Capsule

Geobacillus Stearothermophilus 0.4ml Capsule Specification

  • Physical State
  • Solid Capsule
  • Storage Instructions
  • Store at 2-8C, protect from light
  • Packaging Type
  • Blister Pack / Strip
  • Purity
  • 98%
  • Usage
  • For monitoring efficacy of steam sterilization processes
  • Shelf Life
  • 18 months
  • Ph Level
  • Neutral
  • Size
  • 0.4 ml Capsule
  • Grade
  • Pharmaceutical
  • Type
  • Biological Indicator
  • Application
  • Biological indicator for sterilization validation
  • Appearance
  • Capsule
  • Purity(%)
  • 100%
  • Population per capsule
  • 1.0 x 10^6 spores
  • Intended Use
  • Single-use only
  • Compatible Process
  • Steam/autoclave sterilization (121C and above)
  • Organism
  • Geobacillus stearothermophilus spores
  • Sterility
  • Non-sterile
  • Indicator Type
  • Biological Indicator Capsule
  • Color
  • Opaque White
 
 

About Geobacillus Stearothermophilus 0.4ml Capsule

With our rich industry experience and knowledge, we are engaged in offering high-quality Geobacillus Stearothermophilus 0.4ml Capsule. This capsule is available in various sizes, shapes, designs and other customized specifications to fulfill the need of our valued end customers. It is widely demanded in the market due to its crack resistant nature, leak resistance and lightweight. In order to ensure its eco-friendly nature, our offered Geobacillus Stearothermophilus 0.4ml Capsule is tested on different parameters.

Features:
  • Easy to fit
  • Ideal for monitoring the all sterilization process
  • Available in 0.4ml sizes

Technical Specifications

Crosstex Code

OS1-50-06

Volume

0.4 ml

Shelf Life

24 Months

Packaging Type

Box



Effective Steam Sterilization Monitoring

This biological indicator capsule provides reliable confirmation of steam or autoclave sterilization effectiveness, using Geobacillus stearothermophilus spores as a challenge organism. It helps users fulfill regulatory and quality standards by verifying that sterilization parameters meet stringent safety requirements.


Simple, Ready-to-Use Design

Housed in a compact, opaque white 0.4ml solid capsule, each indicator is intended for single-use, ensuring accuracy and minimizing handling risks. Its convenient blister pack/strip packaging keeps capsules protected from light and contaminants, while also allowing for easy distribution and storage.


Assured Purity and Reliability

With a pharmaceutical grade and purity of up to 100%, these capsules offer dependable results when monitoring sterilization procedures. Each capsule is made to strict quality standards, ensuring consistency and reliability in every batch.

FAQ's of Geobacillus Stearothermophilus 0.4ml Capsule:


Q: How do I use the Geobacillus stearothermophilus 0.4ml Capsule as a biological indicator?

A: Insert the capsule into the location within your steam sterilizer (autoclave) that is most difficult to sterilize. Run the sterilization cycle at 121C or higher, then remove the capsule and process it according to your laboratory protocols to detect surviving spores, validating sterilization efficacy.

Q: What is the benefit of using Geobacillus stearothermophilus spores in biological indicators?

A: Geobacillus stearothermophilus spores are highly resistant to heat, making them ideal for challenging steam sterilization processes. Their use ensures that your sterilization process is effective against even the most robust microbial contaminants.

Q: When should I use this biological indicator capsule?

A: Use this capsule whenever you need to validate or monitor the efficacy of your steam/autoclave sterilization cycles, especially during routine checks, equipment qualification, or after repairs and maintenance of sterilizers.

Q: Where should I store the Geobacillus stearothermophilus capsules?

A: Store the capsules at a temperature between 2-8C and protect them from direct light to preserve their viability and ensure accurate results.

Q: What is the shelf life of the capsules and how should they be packaged?

A: Each capsule has a shelf life of 18 months from the date of manufacture and comes in protective blister packs or strips to safeguard against contamination and environmental exposure.

Q: Can the capsules be reused or are they single-use only?

A: The Geobacillus stearothermophilus biological indicator capsule is intended for single-use only, ensuring that each test is free from cross-contamination.

Q: What precautions should I follow during storage and handling?

A: Always keep the product at the recommended temperature range (2-8C), avoid exposure to light, and handle the capsules with care to prevent loss of viability or contamination before use.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Biological & Chemical Indicators Category

Quantitative ATCC Cultures for GPT and PEC

Quantitative ATCC Cultures for GPT and PEC

Price 45000 INR / Pack

Minimum Order Quantity : 1 Pack

Usage : Laboratory

Type : Other, Microbial control, Other, Quantitative ATCC Cultures for GPT and PEC

Application : Quantitative ATCC Cultures for GPT

Packaging Type : Kwik stick

Pyrogen Free Micropipette Tips

Pyrogen Free Micropipette Tips

Price 400 INR / Pack

Minimum Order Quantity : 50 Packs

Usage : Laboratory liquid handling

Type : Other, Micropipette Tips, Other, single

Application : Chemical Laboratory

Packaging Type : Pack of 100

Quantitative ATCC Culture

Quantitative ATCC Culture

Price 6500 INR / Pack

Minimum Order Quantity : 2 Packs

Usage : Industrial

Application : Insect Control

Packaging Type : Bottle

Biological Indicator Strips

Biological Indicator Strips

Price 60 INR

Minimum Order Quantity : 100 Pieces

Usage : Industrial

Type : Other, Biological Indicator



Back to top